WTP

Overview | F.A.Q.'s | Download Manual

Materials
Meter Body PVC Schedule 80 fittings
Turbine Insert PVC (Polypro in 2" size)
Turbine Rotor Kynar (PVDF)
Shafts Zirconia ceramic
Bearings Sapphire journal, ruby endstone

Maximum Pressure

150 psi @ 75° F
(10 bar @ 24° C) (see chart)

Maximum Temperature 120° F (50° C) (see chart)

Accuracy ± 1% of full scale

Flow Range (Gallons Per Minute)

2" 3" 4" 6"
Minimum 2 3 6 12
Maximum 150 400 600 1200

Flow Range (Liters Per Minute)

2" 3" 4" 6"
Minimum 8 11 23 46
Maximum 568 1514 2271 4542

ELECTRONIC OPTIONS:


WT100 (Pulse Output Only)
Power 6-24 Vdc
Pulse Output 0-75 pulse/second current sinking

WT101 (Powered Rate/Totalizer)
Power 12-32 Vdc (for 4 mA DC min);
24-32 Vdc (for accuracy of 4-20 mA loop)
Rate 6-digit autorange
Total 8-digit
Memory Non-volatile (no battery needed)
Pulse Output 0.1 second open collector (scaled);
0-75 pulse/second passthrough (unscaled); High or low alarm
Analog Output 4-20 mA loop (24-32 Vdc required)

WT102 (Blind 4-20 Transmitter)
Power 24-36 Vdc (isolated)
Analog Output 4-20 mA loop
Response Time 2-60 seconds, 90% of full scale (depends on input averaging)

WT104 (Battery-powered Rate/Totalizer)
Power 3.6 Vdc Lithium battery; replaceable, 3-5 year life
Rate 6-digit autorange
Total 8-digit
Pulse Output 0.1 second open collector (scaled);
0-75 pulse/second passthrough (unscaled); High or low alarm

HOW TO ORDER
WTP(Electronics)-(Size)-(Option)
 
Electronics Code Size Code Option Code
 
100 (pulse only) -200=2" -04=Micropower sensor (use w/WTP100)
101 (powered rate/totalizer) -300=3" -18=Flanged ends
102 (blind 4-20 transmitter) -400=4" -119=Carbide shaft (3-6")
104 (battery rate/totalizer) -600=6"  


© 2000 SeaMetrics Inc., All Rights Reserved.