WTS

Overview | F.A.Q.'s | Download Manual

Materials
Meter Body 304SS Stainless, 316SS optional
Turbine Insert CF8M Cast Stainless
Turbine Rotor Kynar (PVDF)
Shafts Zirconia ceramic
Bearings Sapphire journal, ruby endstone

Maximum Pressure 200 psi (14 bar)

Maximum Temperature 200° F (93° C)

Accuracy ± 1% of full scale

Flow Range (Gallons Per Minute)  
2" 3" 4" 6" 8"
Minimum 2 3 6 12 30
Maximum 150 400 600 1200 3000

Flow Range (Liters Per Minute)

2" 3" 4" 6" 8"
Minimum 8 11 23 46 114
Maximum 568 1514 2271 4542 11000


ELECTRONIC OPTIONS:


WT100 (Pulse Output Only)

Power 6-24 Vdc
Pulse Output 0-75 pulse/second current sinking


WT101 (Powered Rate/Totalizer)

Power 12-32 Vdc (for 4 mA DC min);
24-32 Vdc (for accuracy of 4-20 mA loop)
Rate 6-digit autorange
Total 8-digit
Memory Non-volatile (no battery needed)
Pulse Output 0.1 second open collector (scaled);
0-75 pulse/second passthrough (unscaled); High or low alarm
Analog Output 4-20 mA loop (24-32 Vdc required)


WT102 (Blind 4-20 Transmitter)

Power 24-36 Vdc (isolated)
Analog Output 4-20 mA loop
Response Time 2-60 seconds, 90% of full scale (depends on input averaging)


WT104 (Battery-powered Rate/Totalizer)

Power 3.6 Vdc Lithium battery; replaceable, 3-5 year life
Rate 6-digit autorange
Total 8-digit
Pulse Output 0.1 second open collector (scaled);
0-75 pulse/second passthrough (unscaled); High or low alarm

Cable #22 AWG 3-con, 18 ft; 2000' max run

HOW TO ORDER
WTS(Electronics)-(Size)-(Option)
 
Electronics Code Size Code Option Code
 
100 (pulse only) -200=2" -04=Micropower sensor (use w/WTS100)
101 (powered rate/totalizer) -300=3" -14=All 316SS
102 (blind 4-20 transmitter) -400=4" -20=Flanged ends (2" only)
104 (battery rate/totalizer) -600=6"  
  -800=8"  